Laboratories and facilities

Research DiSTAR

List of Laboratories
 
LIST OF LABORATORIES
  RESPONSIBLE CO - RESPONSIBLE UBICAZIONE
AAS-ICP/OES Morra Monetti L1 4.LAB.56
Deionized water Monetti Monetti L1 4.LAB.54
Clean Room D’Antonio Di Renzo L1 4.LAB.47/48
Geomaterial characterization Colella Di Benedetto L2 T.LAB.03
Fine Chemistry 1 Parente Mondillo L1 4.LAB.77
Fine Chemistry 2 Balassone Francese L1 4.LAB.59
Chemistry 1 Aiello Monetti L3 3.LAB.31
Chemistry 2 Di Donato Monetti L3 3.LAB.08
Ovens and Muffle furnaces De Bonis Colella L2 T.LAB.04
FT-IR Izzo Francese L1 4.LAB.57
Environmental Geochemistry Albanese Albanese L3 3.LAB.10
Applied Geophysics 1 Di Maio La Manna L3 3.LAB.07
Applied Geophysics 2 Fedi Paoletti L2 T.LAB.18
Applied Geology and Geotechnics De Vita Di Clemente L2 T.LAB.13
ICP-OES Morra Monetti L1 4.LAB.55
Fluid and melt inclusions Rossi Lima L3 3.LAB.05
Meteorological Observatory Scafetta Viola San Marcellino
Optical Microscopy 1 Fedele Guarino L1 4.LAB.60
Optical Microscopy 2 Barra Monetti L1 4.LAB.58
Microscopy of sediments (Optical 3) Iannace Parente L3 1.LAB.15
Sample preparation Franciosi Francese L1 4.LAB.46
SEM Petrosino De Gennaro L2 T.LAB.06
Thin sections Vitale Bravi L2 T.LAB.15
Mass Spectrometry D’Antonio Di Renzo L1 4.LAB.52
Rock cutting and grinding Franciosi Bravi L2 T.LAB.16
Chemical treatment of sediments Russo Ermolli Russo Ermolli L3 3.LAB.29
Experimental Volcanology Petrosino Petrosino L3 3.LAB.21
Virtual MODEling Laboratory Repola      
XRD Cappelletti Monetti L2 T.LAB.05
XRF Cucciniello Fedele L2 T.LAB.07
Plasma Emission Spectroscopy (ICP-OES)
Plasma Emission Spectroscopy (ICP-OES)
Responsible: Prof. Vincenzo Morra
Co-Responsible: Mr Vincenzo Monetti
Location: L1. 4-55 
 
 

Performed activities:

Qualitative and quantitative geochemical analyses of geological samples (rocks, minerals, natural, thermal, underground and marine waters). Analyses are carried out within the framework of Department research projects, services for third parties and research agreements.

Available Equipments:

ICP-OES Avio 200 Perkin-Elmer optical emission spectrometer

Mettler AC 100 analytical balance

ICP-OES (Inductively Coupled Plasma - Optical Emission Spectroscopy

This analytical technique is used to determine the qualitative and quantitative elemental composition of samples generally in the liquid state. As far as polymeric samples are concerned it is necessary to follow a careful sample preparation procedure, consisting of a mineralization step. The analytical data are obtained by introducing the sample in the nebulizer where it is converted into an aerosol of droplets through a process called nebulization. The aerosol is then transported to the plasma where the atoms and ions undergo an excitation process followed by the emission of characteristic radiations. The radiation is detected and converted into an electrical signal which is used to trace and identify the analyte that emitted this radiation and, after the construction of an appropriate calibration curve, to its concentration.